NOTE
For automatic bidirectional OTDR testing, two units having the talkset option
and the E80 bidirectional option are required.
Example with 6000 series
Fully automatic bi-directional acquisitions can not be performed with-
out a data connection (see «Data transfer» in the user manual of the
MTS/T-BERD, reference 8000EM02 for example).
Please check that the OTDR function has been selected (see
function" on page
For best measurements and in order to qualify the fiber link and connectors,
launch cables shall be inserted between the OTDR modules and the link.
Summary of the automatic operation procedure
•
Test if both units are linked to the same fiber
•
Consistency verification of the OTDR plug-in between the two units.
•
Consistency verification of acquisition configuration, measurement and files, fiber
and link definition. Then transfer of the master unit configuration to the slave unit
if necessary.
•
Acquisition start on the master unit
Data
26).
User Manual
Chapter 6 Bi-directional OTDR
Description of the measurement
Tested Fiber
78000010220 Rev. 024
"Activating the OTDR