Fiber Characterization Automated Test Sequence using the Link Characterization Script
Configuring the Job Type & Link Description
1
Check Fiber Span testing is defined in Job Type parameter.
2
Enter Link Description on both units
Figure 250
Link Description parameters
Enter Cable/Link Id
Enter Fiber information
Enter both end
locations
Add job/work# info. &
comments if required
Make sure they are both identical for test documentation consistency.
All test files will be saved into the directory automatically created as
per [Local Fiber Id] [Local Fiber #] if fiber span, and [Local Cable_Id] if
cable commision.
Configuring the "Results" Summary table
This summary table enables to review selected values at the end of the test sequence.
A Pass/Fail status is associated to the table.
1
Press the softkey Select Results to Display to access the selection list.
2
Highlight one parameter in the column .
3
Press the soft key Add Result in order to select the parameter and see it in the
column .
4
Repeat steps 1 to 3 until you have selected all the parameters. Maximum 7.
5
Press the soft key Validate in order to acknowledge the selection.
See
Figure 235 on page
6
Press Exit to return to Fiber Characterization screen.
472.
User Manual
Chapter 17 Fiber Characterization
78000010220 Rev. 024
Enter Fiber
number
Select bit
rate in drop
down list