Table: display of the table alone
Figure 164
OSCA Results - Table

Channel detection threshold

On the trace, some peaks corresponding to noise could be mistaken for channels. It is
therefore necessary to fix a power threshold level: only peaks that exceed this threshold
will be considered as channels and included in the table of results.
To display or modify this threshold, press the S
Modify the value to position it on

Display of a grid

The display window of the trace can include a grid to facilitate verification of the position
of the channels. Several grids are possible (see the chapter

Display of total power between cursors

To display on the trace the total power between the two cursors A and B:
1
Place the cursors at the desired positions.
2
Press the
The space between the trace and the two cursors is greyed out and the power is
displayed in the form "P=-4.95dBm".
1.The "Auto" value is obtained by continuing to reduce the value of the threshold
below the minimum value of -79.9 dBm
Chapter 9 OSCA-710 Optical Spectrum Measurement
Auto
Advanced
key, then
User Manual
key, then select
ETUP
1
or fix a threshold value.
Total Power
A<--->B.
78000010220 Rev. 024
Trace display functions
Signal
threshold.
"Grid" on page
315)