Figure 168
Result trace of an OSNR measurement
The table will show the following results:
Wavelen/Freq: will be displayed in nm or in THz
Spacing: channel spacing in THz
Level: total integrated channel power in dBm
Noise: in-band noise power normalized to 0.1nm noise bandwidth
OSNR: measured OSNR

File Management

Storing OSCA measurements

If Auto store has been selected, then results will be saved automatically.
If not, or if you want to save the results under another name, directory etc.:
1
Click on F
2
Click on
3
Enter a filename in the edition keypad.
4
Click on Enter to save the trace.
The trace is saved with the extension ".DCR"
Chapter 9 OSCA-710 Optical Spectrum Measurement
key
ILE
Save
> Save.
User Manual
78000010220 Rev. 024
File Management
331