Chapter 3 Reflectometry measurements
Configuring the reflectometry test
Wavelength (nm)
Corning SMF-28
Corning SMF-DS
Corning SMF-LS
Corning-Leaf
Draka SMF
Draka Longline
Draka Teralight
Draka Benbright
Fitel Furukawa
OFS Lucent Allwave
Lucent Truewave
SpecTran SM
Sterlite
Sumitomo Litespec
Sumitomo Pure
Figure 21
Wavelength (nm)
Corning 62.5
Corning 50
SpecTran 62.5
Generic 50
Generic 62.5
Generic OM1-62/125
Generic OM2-3- 4 50/125
Scatter coefficient
User
Auto
40
1310 SM
1360 - 1510 SM
1.46750
1.46810
1.47180
1.47110
1.47100
1.47000
1.46890
1.46840
1.46750
1.46800
1.46700
1.46700
1.46820
1.46820
1.46750
1.46750
1.47000
1.47000
1.46750
1.46750
1.47100
1.47100
1.46750
1.46810
1.46700
1.46700
1.46600
1.46600
1.46600
1.46600
Predefined index values (Multi Mode)
Selects for each wavelength, the backscatter coefficient of -99 dB to
-50 dB by increments of 0.1dB. Modification of the backscatter coeffi-
cient K changes the measurements of reflectance and ORL.
Backscatter coefficients are selected automatically for each wave-
length.
User Manual
1550 SM
1.46810
1.47110
1.47000
1.46840
1.46800
1.46710
1.46830
1.46800
1.47000
1.46750
1.47000
1.46810
1.46750
1.46700
1.46700
850 MM
1.50140
1.48970
1.49600
1.49000
1.49000
1.49600
1.48200
78000010220 Rev. 024
1625 - 1650 SM
1.46810
1.47110
1.47000
1.46900
1.46850
1.46750
1.46850
1.46850
1.47000
1.46850
1.47000
1.46810
1.46750
1.47000
1.47000
1300 MM
1.49660
1.48560
1.49100
1.48600
1.48700
1.49100
1.47700