Site Info Labels - Viavi 8100 V2 Series User Manual

Portable, modular platform designed for the construction, validation and maintenance of optical fiber networks
Hide thumbs Also See for 8100 V2 Series:
Table of Contents

Advertisement

Chapter 3 Reflectometry measurements
Enterprise-SLM Software option (T-BERD/MTS-6000A V2 only)
Splice
Loss
Default
> 0.20 dB
TIA-568.3
> 0.30 dB
TIA-563.3
RL35
ISO/IEC
11801
(2002)
> 0.30 dB
ISO/IEC
11801
(2010)
ISO/IEC
14763-3
(2006)
> 0.30 dB
ISO/IEC
14763-3
(2014)
If results are above the thresholds, they will be highlighted in red in the table of results,
and the icon
If all the results lie within the thresholds (no result is in red), results are displayed in
green in the table and the icon is

Site Info Labels

In the Setup page, press Site Info Labels softkey (if one parameter is selected in the
current screen, press Top Menu soft key to display the right menu keys and click on Site
Info Labels).
The Site Info Labels screen allows configuring the Site Properties and the Labeling.
110
Connector
Loss
SM: > 1.00 dB/km
> 0.50 dB
MM: 850 nm > 3.50 dB/km
1300 nm: > 1.50 dB/km
SM: > 1.00 dB/km
> 0.75 dB
MM: 850 nm > 3.50 dB/km
1300 nm: > 1.50 dB/km
SM: > 1.00 dB/km
> 0.75 dB
MM: 850 nm > 3.50 dB/km
1300 nm: > 1.50 dB/km
SM: > 0.40 dB/km
> 0.50 dB
MM: 850 nm > 3.50 dB/km
1300 nm: > 1.50 dB/km
SM: > 1.00 dB/km
> 0.50 dB
MM: 850 nm > 3.50 dB/km
1300 nm: > 1.50 dB/km
SM: > 0.40 dB/km
> 0.75 dB
MM: 850 nm > 3.50 dB/km
1300 nm: > 1.50 dB/km
will appear at the top right of the screen.
User Manual
Slope
Reflectance
> -35 dB
> -35 dB
> -35 dB
.
78000010220 Rev. 024
ORL
SM
< 27 dB
No
No
40 km
No
No
5 km
No
No
5 km
Distance
MM
N/A
2 km
2 km
2 km

Advertisement

Table of Contents
loading

Table of Contents