Figure 190
Example of OSA BBS Results
Instantaneous
Effective DGD
measurement
for each channel
The OSA results screen is split in 3 main areas. from top to bottom:
1
The information bar with:
–
frequency range
–
fiber number (N:)
–
date and time of acquisition.
–
file name (if result stored in memory)
2
The trace
3
The table of results contains the following results:
–
the channel number
–
the frequency or wavelength tested, according to the unit selected in the
Setup menu
–
the effective DGD (in ps)
If more than one scan is performed, statistics are available and can be displayed:
1
Press the menu key
2
Select Stat. On with the menu key
The menu key
The statistics for effective DGD display.
Performing a PMD Measurement with BBS and IPMD Module
Optical Spectrum Analysis with Frequency
.
turns active.
User Manual
Chapter 11 I-PMD Measurement
.
78000010220 Rev. 024
377