Chapter 3 Reflectometry measurements
Smart Link Cable Option
2
Press S
–
Configure the OTDR Acquisition parameters (see
–
Configure the OTDR Alarms parameters (see
–
Configure the OTDR File parameters (see
3
Press Link Cable menu key
4
Configure the Link Description parameters (see
5
In the new window Project Information, configure the project as required:
•
Use the Edition keypad to enter a name for Technician Id / Job Id / Contactor Id
/ Sub Contractor Id / Engineer Id.
•
Define the Display mode of the Project: Numbering or Labelling.
If Numbering is defined:
–
–
If Labelling is defined:
–
•
Press the right direction key to enter a Comment if necessary, using the edition
keypad.
Figure 91
Cable SLM Setup
158
hard key to display the OTDR configuration screen and:
ETUP
On the parameter Start Fiber, press Edit Number soft key to enter the
number of the first fiber of the cable to be tested (Min 1 / Max 100).
On the parameter Number Of Fibers, press Edit Number soft key to enter
the total number of fibers of the cable (Min 1 / Max 100).
On the parameter Fiber Count, select the type of connector: Simplex /
Duplex / MPO (8/12) / MPO (12/12) / MPO (20/24) / MPO (24/24)
User Manual
page
.
Cable Commissioning
configuration
78000010220 Rev. 024
page
32)
page
36)
48)
page
43)