Chapter 17 Fiber Characterization
Fiber Characterization Automated Test Sequence using the Link Characterization Script
Measurement will start automatically,, when the far end BBS is on.
2
Press No when message prompt appears
testing.
3
Notify the far end user to do the same.
Testing next fiber
Before testing next fiber, make sure the fiber description (fiber num-
ber, location...) has been correctly setup in the Link Characterization
Script setup page.
1
Repeat steps 1 to 9 to test the next fiber
Users can press Yes when the message prompts to
sequence a new test with consecutive fiber number..
Fiber Characterization - No datalink
Once the referencing measurements have been done, a fiber characterization can be
performed, in a semi automatic mode, using a T-BERD 8000 V2 at one end and a T-
BERD/MTS 6000A V2 at the other end, or using two T-BERD/MTS 8000 V2.
Setting the OTDR/IL/ORL Pass/Fail criteria
If it has not already been done, the alarm parameters must be configured for OTDR and
IL/ORL.
NOTE
You don't need to go through this step if the pass/fail criteria had previously
been loaded.
1
Press the S
2
Go to the FiberComplete tab on both units
3
Configure the FCOMP Thresholds parameters as Default or enter your own
criteria
488
hard key on both units
ETUP
User Manual
78000010220 Rev. 024
to stop