Viavi 8100 V2 Series User Manual page 73

Portable, modular platform designed for the construction, validation and maintenance of optical fiber networks
Hide thumbs Also See for 8100 V2 Series:
Table of Contents

Advertisement

Alarms > Threshold
None
Fail
User: define your own thresholds values for one or several elements: Splice /
Connector / Reflectance / Slope / Fiber Length Min and Max / Total Loss Min and
Max / ORL
TIA-568 3 / TIA-568 3.RL35 / ISO/IEC 11801 2002 or 2010 / ISO/IEC 14763-3
2006 or 2014 / Default: Select one of this parameter to configure the alarm
thresholds with predefined values:
Table 1
Singlemode Modules
Default
TIA-568.3
TIA-568.3 RL35
ISO/IEC 11801
(2002)
ISO/IEC 11801
(2010)
ISO/IEC 14763-3
(2006)
ISO/IEC 14763-3
(2014)
1. This parameter is not available in OEO-OTDR configuration
The alarm function is not active.
This menu lists possible major alarm thresholds that the user could
select. If results are above those thresholds, they will be highlighted
in red in the table of results, and the icon
right of the screen.
If Fail is selected, select in the Threshold parameter to defined values
either manually or according to standards:
Splice
Connector loss Reflectance
Loss
> 0.20 dB
> 0.50 dB
> 0.75 dB
> 0.75 dB
> 0.75 dB
> 0.30 dB
> 0.50 dB
> 0.50 dB
> 0.75 dB
User Manual
Chapter 3 Reflectometry measurements
Configuring the reflectometry test
> - 35 dB
> 1.00 dB/km
No
> 1.00 dB/km
> - 35 dB
> 1.00 dB/km
No
> 1.00 dB/km
> - 35 dB
> 0.40 dB/km
No
> 1.00 dB/km
No
> 0.40 dB/km
78000010220 Rev. 024
will appear at the top
1
Slope
ORL
< 27 dB
No
No
Mux/
Demux
No
-
-
-
-
-
-
37