Performing a PMD Measurement with BBS and
IPMD Module
The following modules apply:
•
E81PMD with E81PSM
Handheld or module broadband sources can be used to perform PMD measurements:
•
OBS-55
•
OBS-500
•
OBS-550
•
81BBS2A (the 81BBS1A cannot be used for this measurement)
The following procedure considers the use of an OBS-5xx type source.
Remote operator
1
Inspect and clean connectors with appropriate methods as described in IEC
61300-3-35
2
Connect the fiber under test to the optical connector of the broadband source
using required mating solution such as fiber patchcord.
3
Press the O
4
Press Laser On/Off of the OBS-55 or the "Active" button of the OBS-5x0 to acti-
vate the source transmission.
NOTE
Make sure the test mode is set to "PMD" when using the OBS-500 or OBS-
550.
Local operator
1
Inspect and clean connectors with appropriate methods as described in IEC
61300-3-35
2
Connect the fiber under test to the optical connector of the test module using
required mating solution such as a fiber patchcord, as shown in
page
Performing a PMD Measurement with BBS and IPMD Module
/O
button to switch on the OBS-5XX broadband source.
N
FF
376.
User Manual
Chapter 11 I-PMD Measurement
78000010220 Rev. 024
Figure 189 on
375