Fiber Characterization Automated Test Sequence using the Link Characterization Script
On the T-BERD/MTS 6000A V2
7
When notified by the 8000 V2 user, touch the softkey
mode as AP
8
Notify the far end user
On the T-BERD/MTS 8000 V2
9
Press Yes to the message
10
Notify 6000A user when the prompt appears
press Yes until far end user confirmed CD source function is activated
On the T-BERD/MTS 6000A V2
11
When notified by the 8000 V2 user, touch the softkey
mode as CD
12
Notify the far end user
On the T-BERD/MTS 8000 V2
13
Press Yes to the message
14
Press No when message prompt appears
testing
15
Notify the far end user
On the T-BERD/MTS 6000A V2
16
When notified by the 8000 user, press
17
Press No when message prompt appears
testing
Testing next fiber
Before testing next fiber, make sure the fiber description (fiber num-
ber, location...) has been correctly setup in the Link Characterization
Script setup page.
1
Repeat steps 1 to 24 to test the next fiber
Users can press Yes when the message prompts to sequence
a new test with consecutive fiber number..
User Manual
Chapter 17 Fiber Characterization
to start AP measurement
to start CD measurement
.
78000010220 Rev. 024
to position the test
but DO NOT
to position the test
to stop
to stop
493