Chapter 17 Fiber Characterization
Fiber Characterization Automated Test Sequence using the Link Characterization Script
b
c
Upon completion of PMD test, instruct user at far end to press AP mode of opera-
tion on light source.
d
Upon completion of AP test, instruct user at far end to press CD mode of opera-
tion on light source.
e
Upon completion of CD test, Result screen appears.
3
If more fibers are to be tested press Yes and fiber number automatically incre-
ments.
If no more fiber is to be tested press No and a summary of the results is visible.
4
Press soft key Exit to exit the link characterization script.
To see details of the tests, press R
of the on-screen.
Fiber Characterization with datalink
Once the referencing measurements have been done, a fiber characterization can be
performed, in an automatic mode, using a T-BERD 8000 V2 at one end and a T-BERD/
MTS 6000A V2 at the other end.
Connecting the Optical Talkset and Datalink
1
Connect the optical talkset port of each mainframe (labeled "TS") using a spare
fiber.
2
When both units are connected, press H
3
Select the function to activate by touching with your finger or stylus.
4
Touch a second time to turn the icon yellow
482
When asked to "CHECK PMD SOURCE", contact far end user to connect
OBS-550/500 light source. Turn light source on, ensure BB mode of opera-
tion, and set for PMD mode and press Activate. Red light will turn on indi-
cating source is active.
Press Yes to continue PMD test.
Press Yes to continue AP test.
Press Yes to continue CD test.
User Manual
hard key and application soft key at the bottom
ESULTS
on the 8000 V2 unit
OME