Chapter 14 CD measurements using phase shift method
Configuring the CD test
Manual
NOTE
This parameter cannot be configured if, in Measurements box, the parame-
ter Fiber Length is defined to Unknown.
Inc.Wavelength
Defines the spacing between 2 consecutive measurement points displayed on the graph
and in the table of results.
Measurement Points
Displays the acquisition points on the Delay curve (represented by black crosses).
Yes
No
Show approximation formula
Displays the resulting approximation equation and the correlation coefficient on the
upper left side of the trace.
Yes
No

Saving configuration in a file

Once parameters have been configured, they can be kept in memory and saved in a
configuration file.
This configuration file can then be recalled in order to be recalled for future CD acquisi-
tions.
To save parameters in a configuration file:
1
If necessary, press S
434
Displays results between 2 user defined wavelengths. The user must
then select the inf. wavelength to "start" with and the sup. wave-
length to "end" with.
All the acquisition points are displayed.
No acquisition points visible
Equation is displayed.
Equation is not visible.
to return to Setup page.
ETUP