Chapter 17 Fiber Characterization

Inspect and clean connectors

Inspect and clean connectors
Before connecting a fiber into a test module, inspect and clean the module bulkhead and
the fiber jumper connectors.
1
Connect the P5000i video inspection scope to both units USB port (any)
2
Press H
Press S
3
Activate the Microscope function on both units by touching with your finger or
stylus. Touch the desired test f unction a second time to turn the icon yellow
4
Use the P5000i video inspection scope to verify the connector quality.
5
Use appropriate cleaning material (e.g. IBC™ cleaner, cotton swab, dust air
sprays, etc.) and re-inspect to confirm.
NOTE
See the user manual of the 8000 V2 or 6000A V2 Base-Unit for the P5000i
scope use.

Connect the test modules to the MTAU

To perform a a test sequence with the fiber characterization script, you must connect the
available plug-in modules to MTAU ports as follow:
OTDR Module (Event characterization): PORT A
ODM Module (Chromatic Dispersion / PMD / Attenuation profile): Port B
1
Connect the OTDR module to the MTAU port A with a short jumper.
2
Connect the ODM module to the MTAU port B with a short jumper
NOTE
Leave the port not connected if you don't have the associated test plug-in
module.
The Fiber Characterization function can be used:
460
hard key on the T-BERD/MTS 8000 V2.
OME
hard key on the T-BERD/MTS 6000A V2.
YSTEM
.
User Manual
78000010220 Rev. 024