Chapter 3 Reflectometry measurements
FTTH-SLM Software option
ORL
Splitter Alarm
Splitter 1x2
Splitter 1x4
Splitter 1x8
Splitter 1x16
Splitter 1x32
Splitter 1x64
Link Loss Max
If results are above the thresholds, they will be highlighted in red in the table of results,
and the icon
If all the results lie within the thresholds (no result is in red), results are displayed in
green in the table and the icon is

Link parameters

In the Setup page, press Link softkey (if one parameter is selected in the current screen,
press Top Menu soft key to display the right menu keys and click on Link).
The information entered in the Link Description window concerns the editing and/or the
modifications of the cable and fiber parameters. When a trace is recalled without recall
of the configuration, the parameters of this trace will be present only in its signature.
Test Point / OLT Id / ONT Id / Distribution Id / Feeder Id
Those parameters allow to enter an identification for each element of the network (test
point, OLT, ONT...) using the Edition menu.
146
G.697/G.98x PON & G.697/
Default
IEEE PON
< 27 dB
< 27 dB
> 5.0 dB
> 4.2 dB
> 8.0 dB
> 7.8 dB
> 11.0 dB
> 11.4 dB
> 14.0 dB
> 15.0 dB
> 17.0 dB
> 18.6 dB
> 21.0 dB
> 22.0 dB
Select: No, Manual or:
will appear at the top right of the screen.
User Manual
for G.697/G.98x PON: 20
dB (A) / 25 dB (B) / 30 dB
(C)
for G.697/IEEE PON: 23
dB (PX-10) / 26 dB (PX-
20)
.
78000010220 Rev. 024
TIA-568C & ISO/
IEC 11801