Chapter 14 CD measurements using phase shift method

Performing a CD Measurement

The file has the extension ".OCD", but differs from the CD measurement result
files as it only contains the reference points (the information on the upper part of
the screen are different). See
page" on page

Loading existing reference

The last reference acquisition performed with the Base Unit may be different than the
reference used by the curve one.
In this case, the Acquisition Ref. menu will be different than the Curve Menu, in the
Reference setup page.
You can replace one reference by the other, using specific softkeys:
-
Load Ref From
will be used for the next acquisitions.
- Update Trace With Ref.: apply the reference parameters to the loaded curve.
Performing a CD Measurement
Once the reference measurement is correctly performed:
1
Disconnect the mating sadapter and connect each fiber patchcord to the end of
the fiber under test
2
Press the S
3
Select the appropriate CD test setup according to your application (see
vation and self calibration" on page
4
Press the S
5
Repeat steps 1 to 4 for every fiber to be tested
438
"Saving results and creating a report from results
445.
Trace: the reference which has been used for the curve actually open
button to access the CD configuration menu.
ETUP
/S
button to see the results within a few seconds.
TART
TOP
User Manual
428).
78000010220 Rev. 024