Chapter 21 Technical specifications
OTDR Modules
•
Resolution of cursor: 1 cm max.
•
Sampling resolution (distance between measurement points): from 2 cm, with up
to 256 000 acquisition points.
•
Absolute Accuracy:
–
–
–
•
Relative Accuracy (Multimode):
–
–
Attenuation measurement
•
Dual cursor
•
Mode Automatic, manual, 2-point, 5-point and LSA
•
Display resolution: 0.001 dB
•
Cursor resolution: 0.001 dB
•
Linearity:
–
–
Reflectance measurement
•
Display resolution: 0,01 dB
•
Accuracy: ± 2 dB
550
For OTDR Modules A:
MM part: ±0.33m ± sampling resolution + 1.10
SM part: ±0.5m ± sampling resolution + 1.10
For OTDR Modules B, C, D: ± 0.75m ± sampling resolution ±10
distance (excluding errors of calibration of refractive index of the fiber)
For other modules: ± 1m ± sampling resolution ±10
(excluding errors of calibration of refractive index of the fiber).
Expert Mode
±0.07m ± sampling resolution + 1.10
RDZ Mode
±0.1m ± sampling resolution + 1.10
Multimode
± 0.05 dB/dB
Singlemode
± 0.03 dB/dB
User Manual
–5
-5
x distance
-5
x distance
78000010220 Rev. 024
–5
x distance
x distance
-5
-5
x distance
x