Chapter 21 Technical specifications
OTDR Modules
3 shocks per axis along each of the 3 axes, with power off.
Impacts of 15g, 1/2 sine, duration 11 ms, at 10 second intervals.
Bumps
The Attribute/Descriptor resists the following test:
1,000 bumps per axis along each of the 3 axes, with power off.
Jolts of 15g, 1/2 sine, duration 6 ms, at 1 second intervals.
Vibration
The Attribute/Descriptor resists the following vibration tests:
Complete test comprising 6 cycles along each of the x, y and z axes.
One cycle of 5 to 200 Hz and back to 5 Hz with a sweep duration of one minute
per octave.
3 mm amplitude displacement test, for the range 5 Hz to 9 Hz.
3g acceleration test for the range 10 Hz to 200 Hz.
Flammability
The Attribute/Descriptor housing (in ABS, type V0) does not propagate fire.
IP Protection Index
Index of the IP protection for the Platform 8000: IP32
NOTE
For a higher classification, contact Viavi.