Figure 239
Alarms and Wavelength range configuration

Defining the filenaming and fiber description

1
Go to the FCOMP tab
2
Press the F
3
If needed, press soft key Explorer/Setup to toggle to Setup
4
Configure your File storage mechanism
For 'Filenaming', define your desired string, example: [Orig-
in_Id]_[End_Id]_[Fiber_Id]_[Fiber_Num]
Press the soft key Copy Setup To all in order to update all the test functions
(OTDR, CD, PMD, AP) with this filenaming information.

Starting a test sequence

1
Inspect and clean connectors of the fiber link to measure using the P5000i
inspection scope
2
Connect the fiber under test to each patchcord (one connected to the TB8000
COM port of the MTAU module and one connected the 6000A module C)
On the T-BERD/MTS 8000 V2
1
Go to MTAU tab and select Out A
2
Press the R
3
Go to the FCOMP tab and press the S
sequence
NOTE
IL, ORL and bidirectional OTDR measurements are triggered under FCOMP.
Fiber Characterization Test Sequence in Manual mode
hard key
ILE
hard key
ESULTS
User Manual
Chapter 17 Fiber Characterization
.
/S
button to start the measurement
TART
TOP
78000010220 Rev. 024
477