Acquisition Parameters - Viavi 8100 V2 Series User Manual

Portable, modular platform designed for the construction, validation and maintenance of optical fiber networks
Hide thumbs Also See for 8100 V2 Series:
Table of Contents

Advertisement

Chapter 7 FiberComplete Modules
Configuring the units

Acquisition parameters

Laser
IL/ORL Measurement
ORL standalone: select this parameter to perform exclusively an ORL measure-
ment in unidirectional mode.
IL/ORL Bidir: select this parameter to perform both an ORL and an Insertion
Loss measurement, in bidirectional mode.
Length Measurement select if the fiber length must be measured during the test.
OTDR Measurement Select the measurement method for OTDR.
None.: OTDR measurement is not performed after FiberComplete test.
Unidir.: OTDR measurement is performed in one way: from the primary unit
toward the secondary one.
Bidir.: OTDR measurement is performed with parameters defined in automatic
mode (Quick Link Test) in the two ways: from primary to seconday unit, and from
secondary to primary unit.
OTDR Acquisition
Auto.: OTDR acquisition is performed with parameters defined in automatic
mode (Quick Link Test).
Manual; OTDR measurement is performed with the parameters manually defined
in the OTDR Setup menu (see
No: OTDR measurement is not performed.
Fault Finder
Yes: if a result for Loss and/or ORL exceeds one limit value defined in the
Thresholds parameters (see
function is automatically triggered in order to identify the faulty events.
No: the Fault finder function is not activated (no fault finding occurs, even if one
value exceeds the thresholds).
If «Fault Finder» parameter is set to Yes, the «OTDR» parameter is
automatically set to No, and vice-versa.
226
select the desired wavelength(s).
All: acquisition is performed for all wavelengths available in the
instruments.
Yes: the fiber length will be measured.
No: the fiber length will not be measured during the test.
If OTDR measurement is configured with Unidir or Bidir
parameter, select the acquisition mode for OTDR.
"Configuring the reflectometry test" on page
select if Fault Finder function must be activated.
"Alarms parameters" on page
User Manual
78000010220 Rev. 024
28).
227), the Fault Finder

Advertisement

Table of Contents
loading

Table of Contents