Chapter 11 I-PMD Measurement
I-PMD Activation and Configuration
Noise Shape
Filtered
Unfiltered
Noise Acq. Bandwidth
Reference bandwidth used for the acquisition of noise
Standard
Values lie between 0.05 nm and 1.0 nm.
OSNR meas.type
Selection of OSNR calculation: S / N or (S+N)/N

Splitter Compensation

When the measurement is made through a Test Access Port (also known as a TAP), it
is possible to compensate for the loss induced by this element and to display the actual
power level of the system.
Value
Yes: activation of compensation and selection of value: from 1 to 30 dB (by increments
of 1) or 1 to 99% (by increments of 0.1%).
Unit
Choice of compensation in dB or percentage (%).
Define the Splitter Compensation using the numeric keypad (displayed via the Edit
Number menu key) or left/right direction keys.
For example, with a 10 dB splitter, the results will be augmented by 10 dB. The trace will
be offset upwards by 10 dB. A channel measured at -30 dBm will be displayed -20 dBm.