Recalling OEO traces

Recalling a «.OEO» file:
If the OEO software option is available, loading a «.OEO» file with the
by
View Trace
OEO trace.
Recalling two «.SOR» files:
Wether the OEO software option is available or not, if the two «.SOR» files corre-
sponding to a bi-directional measurement are selected, the key Load Bi-dir. appears.
The OEO trace is then displayed.
NOTE
If both traces are not compatible (not performed using the same wavelength
and pulse width), a error message is displayed <Acquisition parameters for
these two files are different ! >
For further information on File management, see

Troubleshooting

Warning/errors after pressing the key Start

Error message
No data link. Activate con-
nection before S
TART
No tab OEO-OTDR on
remote Platform
Remote Unit not ready
No resource for remote Plat-
form
key will open automatically the OEO-OTDR tab in order to display the
Possible problem
No data connection
No software option
OEO-OTDR on
remote Platform
OTDR resource has
not been selected
OTDR resource is
already being used
User Manual
Chapter 6 Bi-directional OTDR
Chapter 20 "File management"
Possible solution
Go back to
connection
Bi-directional measurement impossi-
ble if no software option on remote
Platform
Go back to
Unit to select the OTDR function
Stop measurement on remote Unit to
free the resource
78000010220 Rev. 024
Troubleshooting
Load
key followed
Home
page to establish a
Home
page on the remote
213