Saving Configuration In A File; Acquisition - Viavi 8100 V2 Series User Manual

Portable, modular platform designed for the construction, validation and maintenance of optical fiber networks
Hide thumbs Also See for 8100 V2 Series:
Table of Contents

Advertisement

Wavelength in nm
Those parameters are valid for all traces present on the screen.

Saving configuration in a file

Once parameters have been configured, they can be kept in memory and saved in a
configuration file.
This configuration file can then be recalled in order to be recalled for future HR OSA
acquisitions.
To save parameters in a configuration file:
1
If necessary, press S
2
Select one parameter in one of the setup page (acquisition, link..)
3
Press Save Config. menu key
4
Enter a name for the configuration file using the edition keypad (max 20 charac-
ters).
NOTE
Configuration file is saved in the directory disk/config/IPMD.
5
Press Enter to validate
A sound is emitted to indicate the file is saved.
The configuration file is saved with the extension ".fo_cfg" (icon
recalled at any time from the Explorer page.

Acquisition

To start a measurement press S
length range and the measurement result will be displayed in graphical and tabular
format.
to return to Setup page.
ETUP
key. The OSA-XXX will scan over the entire wave-
TART
User Manual
Chapter 12 High Resolution OSA Measurement
78000010220 Rev. 024
Acquisition
) and can be
389