Fiber Characterization Automated Test Sequence using the Link Characterization Script
NOTE
The far end 6000A Datalink icon will turn yellow when connection is estab-
lished. Both units will beep to confirm.
NOTE
You can use the optical talkset simultaneously to talk through the spare fiber.
Figure 242
Talkset and Datalink connection
Optical
Talkset
Powermeter
VFL
OTDR module 1310/1550/1625 nm + FiberComplete (IL/ORL)
5
Activate the function
Setting the OTDR/IL/ORL Pass/Fail criteria
If it has not already been done, the alarm parameters must be configured for OTDR and
IL/ORL.
NOTE
You don't need to go through this step if the pass/fail criteria had previously
been loaded.
Datalink Connection with spare fiber
DISPAP (CD/PMD/AP)
OTDR module 1310/1550/
1625 nm + FiberComplete (IL/
ORL) + BBS (CD/PMD/AP)
MTAU 4: Multi-Test Access unit
allowing a single connection/
disconnection of the fiber under
test for multiple measurements
Fiber under test
User Manual
Chapter 17 Fiber Characterization
78000010220 Rev. 024
Optical
Talkset
Powermeter
VFL
483