Viavi 8100 V2 Series User Manual page 212

Portable, modular platform designed for the construction, validation and maintenance of optical fiber networks
Hide thumbs Also See for 8100 V2 Series:
Table of Contents

Advertisement

Chapter 4 Reduced Dead Zone OTDR application
Saving the trace(s) and generating a report
Figure 108
Fast report configuration
a
NOTE
The Save mode is defined to Standard or Combo mode from the Setup > File
page. See
b
c
d
e
3
Once saving is configured as wished, press Save All menu key
4
Enter a name for the file in the edition keypad.
or
176
In the Save Mode parameter, select:
File Only to save exclusively the trace in a asor file.
File + txt to save the trace in a asor file and to generate a txt file of the
results.
File + pdf to save the trace in a asor file and to generate a report in a pdf
format.
All: to save the trace in a asor file and to generate one txt report and one pdf
report.
"Report Layout" on page 51
In the Cable Id parameter, enter/modify the name of the Cable using the
edition keypad.
Modify the Fiber Number / Fiber Code using the key
The parameter is different according to the Cable Structure configuration
(see
"Cable structure" on page
In the Direction parameter, select/modify the direction, to define if the
measurement has been performed from Origin to Extremity (A -> B) or from
Extremity to Origin (B -> A)
In the Location A and Location B parameters, enter/modify the name of
Origin and Extremity.