Chapter 12 High Resolution OSA Measurement
Configuration of the instrument
Time Interval between Scans
This parameter allows to enter a wait period before the measurement start (only active
if Long Term is positioned on Yes, in Continue or Statistics mode)
Increments of 5 seconds up to 1 minute, then increments of 1 minute up to 10
minutes, then increments of 5 minutes up to 60 minutes; then increment of 1 hour
up to 24 hours.
The modification of this parameter automatically modifies the next parameter, Total
Meas. Time, which cannot be modified.

Analysis parameters

In the Setup page, press Analysis softkey (if one parameter is selected in the current
screen, press Top Menu soft key to display the right menu keys and click on Analysis).
Channel Detection
Signal threshold
Threshold of detection of channels (see
Auto.
Manual
Use direction keys or
Min. Channel spacing
Defines the minimum spacing of two adjacent optical channels in the system.
This parameter is also used to set the range for integration to measure the accurate total
signal power of an optical channel. (see table contents
channel power integration will be ±1/2 the min. channel spacing setting left and right to
the channel center frequency.
The measurement result will be displayed in the WDM table as 'Level' in dBm.
1.Attention: all modification of these parameters has immediate repercussions on
the trace and entails the loss of the measurement statistics.
386
1
the threshold is determined automatically.
the threshold can be set from -79.9 to +30 dBm
Edit Number
1
User Manual
"Channel detection threshold" on page
to modify values.
page
78000010220 Rev. 024
399) The window for
395).