Figure 87
SmartLink function
Zone 1
Zone 2
Zone 3
The screen is divided into three zones:
Zone 1: Graphical representation of the link, with icons symbolizing the different
events detected.
Zone 2: Link Table, which gives a summary of results for each wavelength, with
results within/without thresholds in green/red (according to Alarm thresholds
defined in the setup screen).
Zone 3: Alarms table (if any)
If several traces are displayed in overlay, with the same wavelength, then
the Zone 2 indicates the results for each wavelength. The graphical repre-
sentation of the Zone 1 is a combination of multiple pulses and wavelengths
acquisitions.
Getting a diagnostic of an event
Diagnosis is used to provide further information about events and eventual problems,
such as root cause possibilities of a failed optical element.
1
Select the event to be described on the graphic (underlined in yellow).
2
Click on Event Diagnostic soft key
User Manual
Chapter 3 Reflectometry measurements
78000010220 Rev. 024
FTTH-SLM Software option