Chapter 3 Reflectometry measurements
Performing OTDR acquisitions
CAUTION
Before launching a new OTDR acquisition, make sure the trace(s) displayed
have been previously saved if necessary, as the new acquisition will auto-
matically delete the displayed results.
On Results page,in Expert OTDR mode, press the softkey Quick Setup: the
acquisition parameters to be modified are displayed under the results trace.
Figure 32
Results page and Quick Setup menu (Expert OTDR)
1
Once configured, launch the new OTDR test pressing the S
Press again Quick Setup menu key to hide the menu under the trace.

Multi-wavelength acquisition

If the module possesses several lasers, to perform successive acquisitions on all the
wavelengths:
1
In the S
2
Start the acquisition by pressing the S
62
Modify the acquisition parameters wished in the displayed menu: Laser /
Acquisition / Range / Pulse / Time
See
page 33
and
page
menu, on the Laser line, choose several lasers or select All.
ETUP
User Manual
34.
/S
TART
TOP
78000010220 Rev. 024
/S
TART
TOP
button.