Viavi 8100 V2 Series User Manual page 459

Portable, modular platform designed for the construction, validation and maintenance of optical fiber networks
Hide thumbs Also See for 8100 V2 Series:
Table of Contents

Advertisement

A menu displays under the trace.
4
In the menu, configure the file saving (and the report)
Figure 209
Fast report configuration
a
In the Save Mode parameter, select:
File Only to save exclusively the trace in a ats file
File + txt to save the trace in a ats file and to generate a txt file of the results
File + pdf to save the trace in a ats file and to generate a report of the trace
and results in a pdf file
b
In the Cable Id parameter, enter/modify the name of the Cable using the
edition keypad.
c
Modify the Fiber Number using the key
d
In the Direction parameter, select/modify the direction, to define if the
measurement has been performed from Origin to Extremity (A -> B) or from
Extremity to Origin (B -> A)
e
In the Location A and Location B parameters, enter/modify the name of
Origin and Extremity.
5
Once saving is configured as wished, press Save All menu key
6
Enter a name for the file in the edition keypad
or
Click on Auto Filenaming menu key to apply the file name defined in the Setup
screen, in Filenaming parameter (see
7
Press Enter to validate
NOTE
The ats file and the txt or pdf file will have the same name.
The icon
displays during saving process.
User Manual
Chapter 13 Attenuation profile
Saving the trace and generating a report
.
"Filenaming" on page
78000010220 Rev. 024
50)