Chapter 17 Fiber Characterization
Referencing the test functions
The test modules (OTDR, DISPAP) have to be located in the slots clos-
est to the mainframe. Keep the MTAU module at the back slots.
Referencing the test functions
The following test functions require REFERENCING before performing tests:
•
FCOMP - Insertion Loss (IL) and Optical return Loss (ORL)
The IL/ORL Referencing is done to ensure that the IL and ORL of the fiber
jumpers are taken into account for an accurate qualification of the fiber to test.
•
Chromatic Dispersion (CD), Attenuation Profile (AP)
The AP /CD referencing is done to ensure that the far end broadband source is
calibrated with the DISPAP module and the insertion loss of the fiber jumpers are
taken into account for an accurate qualification of the fiber to test.
NOTE
This measurement is a two ended test. Both T-BERD/MTS 8000 V2 Platform
and Broadband Source (OBS Handheld or T-BERD/MTS including the BBS
capability) must be at the same location
Inspect and clean connectors
Before connecting a fiber into a test module, inspect and clean the module bulkhead and
the fiber jumper connectors.
Caution
•
Use the P5000i video inspection scope to verify the connector quality.
•
Use appropriate cleaning material (e.g. IBC™ cleaner, cotton swab, dust air
sprays, etc...) and re-inspect to confirm.