RM0440
Clock source switching conditions:
Switching from HSE or HSI16 to PLL with AHB frequency (HCLK) higher than 80 MHz
Switching from PLL with HCLK higher than 80 MHz to HSE or HSI16
Transition state:
Set the AHB prescaler HPRE[3:0] bits to divide the system frequency by 2
Switch system clock to PLL
Wait for at least 1 µs and then reconfigure AHB prescaler bits to the needed HCLK
frequency
6.2.8

Clock source frequency versus voltage scaling

The following table gives the different clock source frequencies depending on the product
voltage range.
Product voltage range
Range 1 Boost mode
Range 1 normal mode
6.2.9

Clock security system (CSS)

Clock Security System can be activated by software. In this case, the clock detector is
enabled after the HSE oscillator startup delay, and disabled when this oscillator is stopped.
If a failure is detected on the HSE clock, the HSE oscillator is automatically disabled, a clock
failure event is sent to the break input of the advanced-control timers (TIM1/TIM8/TIM20
and TIM15/16/17) and to the hrtim_sys_flt, and an interrupt is generated to inform the
software about the failure (Clock Security System Interrupt CSSI), allowing the MCU to
perform rescue operations. The CSSI is linked to the Cortex
Maskable Interrupt) exception vector.
Note:
Once the CSS is enabled and if the HSE clock fails, the CSS interrupt occurs and a NMI is
automatically generated. The NMI will be executed indefinitely unless the CSS interrupt
pending bit is cleared. As a consequence, in the NMI ISR user must clear the CSS interrupt
by setting the CSSC bit in the
If the HSE oscillator is used directly or indirectly as the system clock (indirectly means: it is
used as PLL input clock, and the PLL clock is used as system clock), a detected failure
causes a switch of the system clock to the HSI16 oscillator, and the disabling of the HSE
oscillator. If the HSE clock (divided or not) is the clock entry of the PLL used as system clock
when the failure occurs, the PLL is disabled too.
6.2.10

Clock security system on LSE

A Clock Security System on LSE can be activated by software writing the LSECSSON bit in
the
Control/status register
RTC software reset, or after a failure detection on LSE. LSECSSON must be written after

Table 40. Clock source frequency

Range 2
Clock interrupt clear register
(RCC_CSR). This bit can be disabled only by a hardware reset or
Clock frequency
HSI16
16 MHz
16 MHz
16 MHz
RM0440 Rev 1
Reset and clock control (RCC)
HSE
48 MHz
170 MHz
48 MHz
150 MHz
26 MHz
26 MHz
®
-M4 with FPU NMI (Non-
(RCC_CICR).
PLL