Commissioning
5.4 Basic commissioning using a PC
Procedure with Startdrive
Proceed as follows to adapt the encoder data:
1. Select the "Motor encoder" screen form.
2. Click the "Encoder data" button.
3. You have access to the following settings in the "Encoder data" screen form:
– You can change all of the encoder data.
– You can select another encoder type. In this screen form, STARTER only lists the
If you wish to set another encoder interface, you must reconfigure the inverter.
You have adapted the encoder data.
5.4.6

Identifying motor data

Identify motor data
Danger to life from machine movements while motor data identification is in progress
The stationary measurement can turn the motor a number of revolutions. The rotating
measurement accelerates the motor up to the rated speed. Secure dangerous machine
parts before starting motor data identification:
• Before switching on, ensure that nobody is working on the machine or located within its
• Secure the machine's working area against unintended access.
• Lower suspended loads to the floor.
82
encoder types that are permitted for the configured interface.
WARNING
working area.
Converter with control units CU240D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34262100B AB