Connecting the PROFINET interface

Condition
The screen of the PROFINET cable must be connected with the protective earth. The solid copper
core must not be scored when the insulation is removed from the core ends.
Description
Listed in the table below are the recommended Ethernet cables.
Table 4-7
Cable type
Industrial Ethernet FC TP Standard Cable GP 2 x 2
Industrial Ethernet FC TP Flexible Cable GP 2 x 2
Industrial Ethernet FC Trailing Cable GP 2 x 2
Industrial Ethernet FC Trailing Cable 2 x 2
Industrial Ethernet FC Marine Cable 2 x 2
4.3.9

Terminal assignment dependent on interface configuration

The inputs and outputs of the frequency converter and the fieldbus interface have specific
functions when set to the factory settings.
When you put the frequency converter into operation, you can change the function of each of
its inputs and outputs and the setting of the fieldbus interface.
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
EMB-
EMB+
Simplied diagram of the motor holding brake connections
Recommended Ethernet cables and cable length
4.3 Electrical Installation
Max. length be‐
Article Number
tween 2 convert‐
ers
100 m (328 ft)
6XV1840-2AH10
85 m (278 ft)
6XV1870–2B
85 m (278 ft)
6XV1870–2D
85 m (278 ft)
6XV1840–3AH10
85 m (278 ft)
6XV1840–4AH10
Installation