Terminal Module For Activation Of "Safe Torque Off" And "Safe Stop 1" (Option K82) - Siemens SINAMICS S150 Operating Instructions Manual

Converter cabinet units 75 kw to 1200 kw
Hide thumbs Also See for SINAMICS S150:
Table of Contents

Advertisement

4.9.21
Terminal module for activation of "Safe Torque Off" and "Safe STOP 1" (option
K82)
Description
The K82 option (terminal module for activating "Safe Torque Off" and "Safe Stop 1" is used
for optically isolated activation via a variable control voltage range of the safety functions
already present in the standard, which can also be used without option K82.
Note
The safety functions must be activated prior to use via parameter assignment. An
acceptance test must be performed and an acceptance log must be created.
See the Operating Instructions "Safety Integrated, SINAMICS S150, G150, G130, S120
Chassis, SINAMICS S120 Cabinet Modules".
Use the option K82 to activate the following safety integrated functions (terminology
according to draft IEC 61800-5-2):
● Safe torque off (STO)
● Safe Stop 1 (SS1, time-controlled)
A list of certified components is available on request from your local Siemens office.
Recommended application
This option is used when:
● Activation will be executed optically isolated in a voltage range of 24 V – 230 V DC/AC.
● You will be working with non-shielded control lines with lengths greater than 30 m.
● The devices will be used in plants with greater spatial elongation (ideal PA not present).
● Fulfillment of the standard DIN EN ISO 13849-1 (formerly EN 954-1) cat. 3 is sufficient
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
Note
The integrated safety functions, starting from the Safety Integrated (SI) input terminals of
the SINAMICS components (Control Unit, Power Module, Motor Module), satisfy the
requirements in accordance with the equipment directive 98/37/EC, the EN 60204-1, DIN
EN ISO 13849-1 category 3 (formerly EN954-1) as well as the requirements for
Performance Level (PL) d, and IEC 61508 SIL2. These are certified by the BGIA.
In combination with the option K82 the requirements specified in machinery directive
98/37/EC, EN 60204-1 as well as in DIN EN ISO 13849-1 category 3 (formerly EN954-1)
are satisfied. The certification of option K82 is in process.
and if there are no requirements in accordance with Safety Integrity level (SIL) 2, IEC
61508, or Performance Level d in accordance with DIN EN ISO 13849-1.
Electrical installation
4.9 Other connections