Configuring test parameters

To select the port
1
Tap the Setup (
choose Rx Settings or Port Configuration.
2
Select Port 1 or Port 2 in Select Port.
Configuring test parameters
Configuration of test parameters described in this section is used in the RFoCPRI mode
including spectrum, spectrogram, and spectrum replayer measurements.

Setting frequency

You can set the frequency with either frequency or channel number. If a frequency to
be set matches to the frequency corresponding to the selected channel standard, the
instrument calculates its channel number and updates the screen with it automatically.
To set the frequency with center frequency
1
Tap Menu > Frequency.
2
Tap Center Frequency and enter a value using the on-screen keyboard.
3
Select a unit from GHz, MHz, kHz, or Hz and tap Apply.
To set the frequency with channel number
1
Tap Menu > Channel.
2
Select the standard channel:
a
b
3
Tap Link between Uplink and Downlink.
4
Tap Channel Number.
5
Enter a value by using the on-screen keyboard and tap Apply.
The ONA-800 automatically displays the corresponding frequency value for the
selected channel number.

Setting reference level

You can set the reference level automatically or manually to optimize the display of the
traces measured.
Page 356
) icon on the side bar of each measurement mode and
Tap Channel Standard. The standard channel window appears.
Tap the band to be measured.
SPA06MA-O User's Guide
22145360, R005
April 2021