Inter-Tel AXXESS Manual page 1183

Hide thumbs Also See for AXXESS:
Table of Contents

Advertisement

Table 6-38:
System
Timers (Continued)
Timer
E&M Transmit Hand-
shake Delay
E&M Wait for Dial Tone
E&M Wink Hold
E&M Wink Timeout
Forward No Answer
GS Dialing Wait After
Connect
GS Tip-Ground
Debounce
GS Transition Delay
Hold
Hold – Alternate
Inactivity Alarm
System Timers and Limits
INTER-TEL
Default
Range
Value
100
2-500 millisec.
(0.002-0.5 sec.)
1000
2-20000 millisec.
(0.002-20 sec.)
214
2-500 millisec.
(0.002-0.5 sec.)
350
2-500 millisec.
(0.002-0.5 sec.)
15
3-255 seconds
30
1-50 tenths
(0.1-5 sec.)
50
10-500 millisec.
(0.001-0.5 sec.)
10
10-500 millisec.
(0.001-0.5 sec.)
60
0-255 seconds
180
0-1000 seconds
60
10-255 seconds
®
®
AXXESS
MANUAL VERSION 11.0 – May 2008
Purpose
This is the minimum delay time between the recogni-
tion of a seizure and the beginning of a handshake
signal. Used only for Wink-Start and Dial-Delay cir-
cuits.
This is how long the E&M circuit will wait for dial tone
before dialing digits on an outgoing call. Only used
on Immediate-Dial circuits with the Dial Tone Wait
option enabled.
Determines the length of a Wink-Start handshake.
Determines the maximum allowed length of wink sig-
nals that are received from the remote circuit. If the
time limit is exceeded, the call will be blocked and the
attempt terminated. Used only for Wink-Start circuits.
Length of time a call waits at an unavailable station
before being forwarded. (Applies to manual call for-
warding only, not system forwarding.)
This is the length of time the system waits after a
ground start trunk has been seized, to place an out-
going call, before dialing digits. (This timer is not
used if the Loop Current Dialtone Detection option is
selected, as described on
page
This is the length of time the system will ignore sub-
sequent attempts to seize a ground start trunk once it
has been seized.
NOTE:
The database contains a station option that
can be set to prevent users from reseizing a trunk. If
selected, the station user cannot reseize a trunk until
it is disconnected by replacing the handset, pressing
the SPKR button (if off hook), or pressing another
trunk button.
This is the amount of time that must elapse after a
disconnection before another call can ring in on that
trunk.
Limits time a call remains on hold before recalling the
station. If set to 0, the call will not recall.
If the station has the Alternate Hold Timer flag
enabled, this limits time a call remains on hold before
recalling the station. If set to 0, the call will not recall.
Limits the time a station can remain off hook and
inactive (after first receiving reorder tones) before
registering a system alarm.
Programming