Ls/Gs Trunk Card; Brief Description; 125 9-L; Facilities - Mitel SX-200 Practices

Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

9
'
LS/GS TRUNK CARD
Brief Description
9.1-
The Loop Start/Ground
Start Trunk Card, part number
9109-01
I -XXX,
mounts
in
any digital bay and interfaces
six trunk circuits to the system.
The card is 158 mm
high x 388 mm long (6.2 in. x 14.5 in.). Figure 9-l
illustrates
the card .and the LS/GS
jumper.
.
,
Facilities
9.2
Facilities
provided
by the LS/GS Trunk Card include:
l
Loop Start or Ground
Start selectable
by jumper
l
M and MM signaling
leads available
l
Trunk activity indicated
by LED (one per trunk)
l
Transient
suppression
on Tip, Ring, and signaling
leads
l
Alarm LED.
Electnkai Description
9.3
The Loop Start/Ground
Start Trunk Card mounts
in any digital bay and interfaces
six
trunk circuits to the system.
Each trunk circuit is programmed
as loop start or ground
start by a jumper
clip prior to installation.
Each trunk has Tip and Ring leads and M and MM leads for additional
signaling,
if
required.
All leads
are protected
by varistors
against
transients
between
line and
ground.
There are also varistors
between
Tip and Ring and between
M and MM. Each
lead is in series with an inductor
near the edge connector
to reduce
electromagnetic
interference
(EMI).
Each trunk has an LED on the front faceplate
of the card that lights to indicate the circuit
is busy. An LED at the bottom
of the faceplate
lights to indicate
a failure on the card.
Operation - loop Start
9.4
To place an outgoing
call, the trunk card places a termination
across tip and ring. The
CO detects
the current flow and responds
with dial tone.
Now the user may begin to
dial.
910949&125--NA
Issue1
Revision
0
125 9-l

Hide quick links:

Advertisement

Table of Contents
loading