Relays - Mitel SX-200 Practices

Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

Universal Card
Table 7-l
DTMF Codes
DTMF Diglt
Data Output
D3 D2 Dl
DO
1
1
1
0
2
1
1
0
I
3
1
1
0
0
5
1
0
1
0
6
1
0
0
1
I
7
I
1
0
0
0
I
6
0
1
1
1
9
0
1
1
0
0
0
1
0
1
*
0
1
0
0
#
0
0
1
1
Relays
There are two general
purpose
relays. When each relay closes,
it connects
a tip and
ring pair together,
as follows:
I
Relay
I
Connection
I
RLYl
T2 to R2
RLY2
T3 to R3
The relay contacts
are rated as follows:
maximum
switching
voltage:
90 V
maximum
cartying
current:
0.5 A
Note:
This relay contact may be connected
only to a secondary
circuit that has no direct
connection to a primaty circuit, and receives its power from a transformer,
convener, or
equivalent isolation device situated within the equipment.
9109-096-l
25-NA
Issue 1
Revision 0
125 7-5