E&M Trunk Module; Brief Description; Facilities; Operation - Mitel SX-200 Practices

Hide thumbs Also See for SX-200:
Table of Contents

Advertisement

Circuit Card Descriptions
E&M Trunk Module
7.7
Brief Description
The E&M Trunk Module
plugs into the Universal
Card, It provides
interface
to Type I
E&M trunks.
The module
has a power rating of 3. Because
of this, a maximum
of three
of these
modules
can be used per Universal
Card.
Facilities
\Facilities
provided
by the E&M Trunk Module
include:
l
Type 1 signaling
l
selectable
gain/loss
plan for normal or satellite
working
trunks
l
selectable
600 ohm or AT&T Complex
Balance
Network
(350 ohms + 1000 ohms in
parallel with 0.21 mF)
l
selectable
2- or 4-wire
transmission
l
on board filter/codec
for analog/digital
and digital/analog
conversions
(mlaw).
Operation
The E&M Trunk Module
is set for the type of trunk in use by a set of eight DIL switches.
The settings
are as follows:
Function
Switches
12345676
PABX to Line Gain
3
dB
oxxxxxxx
-13 dB
lxxxxxxx
Line to PABX Gain
- 4dB
xoxxxxxx
-11 dB
xlxxxxxx
Balance
600
ohm
Complex
xx1 oxxxx
xx01xxxx
Transmission
Signaling
2-wire
4-wire
Type 1
Me5
xxxxl
xxx
xxxxoxxx
xxxxxl
xx
xxxxxoxx
0= open,
I = closed,
x= not applicable
Default
setting for North America
is 00101100
Trunk
Types
The E&M Trunk Module
applies signals to the M lead and monitors
the E lead. In the
on-hook
condition,
the Type I interface
grounds
the M lead; an open presented
to the
E lead indicates
idle, a grounded
E lead indicates
an incoming
call. In the off-hook
condition,
the Type I interface
applies -48 volts to the M lead; a ground
sent to the E
lead indicates
an incoming
seizure.
125
7-6
Revision 0
9109-09&125-NA
Issue 1