ON
OFF
11
1
2
3
5
2
3
5
2
1
3
BODY ELECTRICAL
INSPECTION
1.
If the continuity is not as specified, replace the switch.
10
I01670
2.
5
1
If the continuity is not as specified, replace the switch.
N14863
3.
If the continuity is not as specified, replace the relay.
I24626
-
FOG LIGHT SYSTEM
INSPECT FOG LIGHT SWITCH CONTINUITY
Switch Position
Tester Connection
OFF
ON
Double cab:
INSPECT FOG LIGHT RELAY CONTINUITY
Tester Connection
3 - 5
3 - 5
(When battery voltage is applied to terminals 1 and 2)
Except double cab:
INSPECT FOG LIGHT RELAY (Marking: FOG) CONTI-
NUITY
Tester Connection
3 - 5
3 - 5
(When battery voltage is applied to terminals 1 and 2)
Author :
Specified Condition
10 - 11
No continuity
10 - 11
Continuity
Specified Condition
No continuity
Continuity
Specified Condition
No continuity
Continuity
Date :
BE-49
BE2K5-01