Dell S6100 Configuration Manual page 718

Hide thumbs Also See for S6100:
Table of Contents

Advertisement

Line
Bias Low Warning
threshold
TX Power Low
Warning threshold
Power Low Warning
threshold
Temperature
Voltage
Tx Bias Current
Tx Power
Rx Power
Data Ready state
Bar
Rx LOS state
Tx Fault state
Rate Select state
RS state
Tx Disable state
Temperature High
Alarm Flag
Voltage High Alarm
Flag
Tx Bias High Alarm
Flag
Tx Power High
Alarm Flag
Rx Power High
Alarm Flag
Temperature Low
Alarm Flag
Voltage Low Alarm
Flag
718
Interfaces
Description
Factory-defined setting. Value can differ between SFP and SFP+.
Factory-defined setting. Value can differ between SFP and SFP+.
Factory-defined setting. Value can differ between SFP and SFP+.
Current temperature of the SFPs. If this temperature crosses Temp High alarm/warning
thresholds, the temperature high alarm/warning flag is set to true.
Current voltage of the SFPs. If this voltage crosses voltage high alarm/warning
thresholds, the voltage high alarm/warning flag is set to true.
Present transmission (Tx) bias current of the SFP. If this crosses bias high alarm/warning
thresholds, the TX bias high alarm/warning flag is set to true. If it falls below the low
alarm/warning thresholds, the TX bias low alarm/warning flag is set to true.
Present Tx power of the SFP. If this crosses Tx power alarm/warning thresholds, the Tx
power high alarm/warning flag is set to true. If it falls below the low alarm/warning
thresholds, the Tx power low alarm/ warning flag is set to true.
Present receiving (Rx) power of the SFP. This value is either average Rx power or OMA.
This depends on the Rx Power measurement type displayed above. If this crosses Rx
power alarm/warning thresholds, the Rx power high alarm/warning flag is set to true. If it
falls below the low alarm/warning thresholds, the Rx power low alarm/warning flag is set
to true.
This field indicates that the transceiver has achieved power up and data is ready. This is
set to true if data is ready to be sent and set to false if data is being transmitted.
This is the digital state of the Rx_LOS output pin. This is set to true if the operating
status is down.
This is the digital state of the Tx Fault output pin.
This is the digital state of the SFP rate_select input pin.
This is the reserved digital state of the pin AS(1) per SFF-8079 and RS(1) per SFF-8431.
If the admin status of the port is down then this flag is set to true.
This can be either true or false, depending on the Current voltage value displayed above.
This can be either true or false, depending on the Current Temperature value displayed
above.
This can be either true or false, depending on the present Tx bias current value displayed
above.
This can be either true or false, depending on the Current Tx bias power value displayed
above.
This can be either true or false, depending on the Current Rx power value displayed
above.
This can be either true or false, depending on the Current Temperature value displayed
above.
This can be either true or false, depending on the Current voltage value displayed above.

Advertisement

Table of Contents
loading

Table of Contents