Instrument Messages
Event Messages
–100 to –199, Command Errors
Err#
Message
–100
Command error
–101
Invalid character
–102
Syntax error
–103
Invalid separator
–104
Data type error
–105
GET not allowed
–108
Parameter not allowed
–109
Missing parameter
–110
Command header error
–111
Header separator
error
–112
Program mnemonic too
long
–113
Undefined header
–114
Header suffix out of
range
–115
Unexpected number of
parameters
–120
Numeric data error
–121
Invalid character in
number
–123
Exponent too large
–124
Too many digits
–128
Numeric data not
allowed
108
Verbose/Correction Information
There is a problem with the command. The exact problem cannot be
specifically identified
An invalid character was found in part of the command
An unrecognized command or data type was found, for example a string was
received for a command that doesn't accept strings
The command was supposed to contain a separator but we found an illegal
character. For example, the semicolon was omitted after a command string
A data type differed from what was expected. For example, numeric or string
data was expected, but block data was found
A Group Execute Trigger was received within a program message
More parameters were received than were expected for the command. For
example, the *ESE common command only accepts one parameter, so
sending *ESE 0,1 is not allowed
Fewer parameters were received than required for this command
This is a general error that is generated when a problem is found in a command
header, but no more specific information is available
An illegal character was found in a command where a separator was expected
The command contains a keyword that has more than twelve characters
The command meets the SCPI syntax requirements, but is not valid in the
current measurement environment
The value of a numeric suffix that is attached to a program mnemonic makes
the header invalid. (A suffix is usually units, like Hz or DB)
The number of parameters received does not correspond to the number of
parameters expected.
An error was found in a data element that appears to be numeric. The exact
problem cannot be specifically identified
A character was found that is not valid for the data type. For example, an alpha
in a decimal numeric or a "9" in octal data
The magnitude of an exponent was greater than 32000
The mantissa of a decimal-numeric contained more than 255 digits, excluding
leading zeros
A legal numeric data element was found, but that is not a valid element at this
position in the command
Keysight N9010B EXA Signal Analyzer Service Guide