Upgrading A Tn2312Ap To A Tn2312Bp Ip Server Interface Circuit Pack; Setting Alarm Activation Level; Replacing The Circuit Pack - Avaya S8500 Manual

Migrating to the media server
Hide thumbs Also See for S8500:
Table of Contents

Advertisement

Upgrading a TN2312AP to a TN2312BP IP Server Interface circuit pack

Upgrading a TN2312AP to a TN2312BP IP Server
Interface circuit pack
There may be an occasion when customers may want to upgrade their TN2312AP Internet Protocol
Server Interface (IPSI) circuit pack to a TN2312BP. For an S8700 or S8710 IP-Connect configuration,
the TN2312BP offers new functionality, including emergency transfer and CPE alarming.
The TN2312BP also is required if the customer wants to move from duplex reliability to high reliability
in an IP Connect configuration. But this also requires that the customer use G650 Media Gateways.
You do not need to change any of the IPSI translations, assuming the functionality stays the same.
However, there is a new alarming feature that needs to be administered.
The TN2312BP Internet Protocol Server Interface (IPSI-2) circuit pack is a hot swappable item. You do
not need to power down the media gateway to replace it.

Setting alarm activation level

1
Type
change system-parameters maintenance
change system-parameters maintenance
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Update LSPs When Saving Translations: y
System Clocks/IPSI Interchange: no
2
In the
CPE Alarm Activation Level
depending on the level the customer wants.

Replacing the circuit pack

166
MAINTENANCE-RELATED SYSTEM PARAMETERS
Start Time: 22 : 00
Stop Time: 06 : 00
Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no
CAUTION:
When adding or replacing any hardware and associated cables and adapters, be sure to
ground yourself against electrostatic discharge (ESD) by wearing a grounded wrist strap.
NOTE:
To properly seat a circuit pack, push firmly on the front of the faceplate until the latch
reaches the bottom rail of the carrier. Then close the latch until it is fully engaged.
and press Enter.
field, select none (default), warning, minor, or major,
Migrating to the Avaya S8700 or S8710 Media Server