Avaya S8700 Maintenance Manual page 2257

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

SYS-LINK (System Links)
The status sys-link location command shows the state of both the hardware
paths (current and faulted) along with the state of each of the components in the
hardware path. When analyzing any system link problem:
1. Look for alarms on the components listed under desired hardware path.
2. If any alarms are present, then follow the maintenance procedures for the
alarmed components to clear those alarms first.
3. When every component is alarm free, wait for 3 minutes to allow the links
to recover.
4. Test the system link (test sys-link PCSSpp long clear), and notice any
tests that fail.
5. If there are any failures, fix the problems indicated by the tests and repeat
the procedure.
Error Log Entries and Test to Clear Values
Table 8-595. Maintenance Error Log Entries
Error
Aux
Type
Data
Associated Test
13 (a)
System Link Status
(#985)
257 (b)
513 (c)
772 (d)
1025 (e)
1281 (f)
1537 (g)
1793 (h)
555-233-143
NOTE:
For systems using ATM-EI (TN2305/6 circuit packs) and where link
alarms are present, see
''ATM Tips''
section in
Chapter
Alarm
Level
MINOR
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
''ATM-BCH (ATM B-Channel Trunk)''
4.
On/Off
Board
Test to Clear Value
OFF
OFF
test sys-link UUCSSpp l cl
OFF
test sys-link UUCSSpp l cl
OFF
test sys-link UUCSSpp l cl
OFF
test sys-link UUCSSpp l cl
OFF
test sys-link UUCSSpp l cl
OFF
test sys-link UUCSSpp l cl
OFF
test sys-link UUCSSpp l cl
Issue 1 May 2002