System (System) - Avaya S8700 Maintenance Manual

For multi-connect configurations
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Maintenance-Object Repair Procedures

SYSTEM (System)

MO's Name (in
Alarm Log)
SYSTEM
1.
SYSTEM has no associated alarms and thus appears only in the Error Log. There are no tests
that run on SYSTEM.
The SYSTEM MO is used to log information about system resets, including
interchanges. When software encounters a problem with hardware, or with its
own processes, and requests a restart to clear the problem, an error is logged
under SYSTEM. For example, if there is a loss of clocking in a system with
duplicated servers, the system switches to the other clock and then executes a
level-2 system reset to recover from hardware problems caused by the loss of
clock. Errors logged under SYSTEM can help to determine the cause of a reset.
For more information about interchanges, see:
''Recovery'' on page
''Troubleshooting a Duplicated Server'' on page 4-10
The display initcauses screen should also contain information about the reset.
(See
''display initcauses'' on page
8-1544
Issue 1 May 2002
Alarm
Level
Initial Command to Run
None
None
3-5, including:
''Reset Level 1 (Warm Restart)''
''Reset Level 2 (Cold-2 Restart)''
''Reset Level 4 (MultiVantage Application Reload)''
7-135.)
1
Full Name of MO
System
555-233-143