On a bladed switch, run the slotPowerOff and slotPowerOn commands.
On a nonbladed switch, reboot the switch.
Run the systemVerification command to determine if there is a hardware error.
If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors
are encountered again:
On the SilkWorm 12000, 24000, and 48000, replace the blade FRU.
On the SilkWorm 3900, replace the motherboard FRU.
On the SilkWorm 200E, 3016, 3250, 3850, or 4100, replace the switch.
Severity
ERROR
BL-1016
Message
<timestamp>, [BL-1016], <sequence-number>, FFDC, CRITICAL, <system-
name>, Blade port <port number> in slot <slot number> failed to
enable.
Probable
Indicates that the specified blade port has failed to get enabled.
Cause
Recommended
Make sure that the blade is seated correctly.
Action
If the blade is seated correctly, reboot or power cycle the blade.
Run the systemVerification command to verify that the blade does not have hardware problems. Refer
to the Fabric OS Command Reference for more information on this command.
If the message persists, replace the blade.
Severity
CRITICAL
BL-1017
Message
<timestamp>, [BL-1017], <sequence-number>,, INFO, <system-name>,
Slot <slot number> Initializing...
Probable
Indicates that the slot has started initializing the ports.
Cause
Recommended
No action is required.