Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 303

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

HIL-1208
Message
<timestamp>, [HIL-1208], <sequence-number>,, INFO, <system-name>,
Fan <fan number> is not faulty.
Probable
Indicates that the fan is not faulty.
Cause
Recommended
This can only occur on switches with non-removable fans. It follows a previous indication of faultiness.
Action
If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.
Severity
INFO
HIL-1301
Message
<timestamp>, [HIL-1301], <sequence-number>,, WARNING, <system-
name>, 1 blower failed or missing. Replace failed or missing blower
assembly immediately.
Probable
Indicates that a fan FRU has failed or has been removed. This message is often preceded by a low speed
Cause
error message. This problem can cause the switch to overheat.
Recommended
Replace the affected fan FRU immediately.
Action
Severity
WARNING
HIL-1302
Message
<timestamp>, [HIL-1302], <sequence-number>,, WARNING, <system-
name>, <count> blowers failed or missing. Replace failed or missing
blower assemblies immediately.
Probable
Indicates that multiple fan FRUs have failed or are missing on a switch. This message is often preceded
Cause
by a low fan speed message.
Recommended
Replace the affected fan FRUs immediately.
Action
Severity
WARNING
Fabric OS Message Reference
Publication Number: 53-1000242-01
28
HIL-1208
28-7

Advertisement

Table of Contents
loading

Table of Contents