73
ZONE-1037
ZONE-1037
Message
<timestamp>, [ZONE-1037], <sequence-number>,, ERROR, <system-name>,
Unable to examine <config file name>: error message <System Error
Message>
Probable
Indicates that the Fabric OS cannot examine the zone configuration file. Typically the zone
Cause
configuration is too large for the memory available on the switch.
Recommended
Reduce the size of the zone database and retry the operation.
Action
Severity
ERROR
ZONE-1038
Message
<timestamp>, [ZONE-1038], <sequence-number>,, ERROR, <system-name>,
Unable to allocate memory for <config file name>: error message
<System Error Message>
Probable
Indicates that the Fabric OS cannot allocate enough memory for the zone configuration file. Typically
Cause
the zone configuration is too large for the memory available on the switch.
Recommended
Reduce the size of the zone database and retry the operation.
Action
Severity
ERROR
ZONE-1039
Message
<timestamp>, [ZONE-1039], <sequence-number>,, ERROR, <system-name>,
Unable to read contents of <config file name>: error message <System
Error Message>
Probable
Indicates that the Fabric OS cannot read the zone configuration file. Typically the zone configuration is
Cause
too large for the memory available on the switch.
Recommended
Reduce the size of the zone database and retry the operation.
Action