Brocade Communications Systems AA979A - StorageWorks SAN Switch 2/8V Reference Manual page 202

Brocade fabric os message reference guide (53-1000242-01, november 2006)
Hide thumbs Also See for AA979A - StorageWorks SAN Switch 2/8V:
Table of Contents

Advertisement

23
FSS-1003
FSS-1003
Message
<timestamp>, [FSS-1003], <sequence-number>,, WARNING, <system-
name>, Component (<component name>) misused the update transaction
(<transaction ID>) without marking the transaction beginning
Probable
Indicates that the FSS has dropped the update because an application has not set the transaction flag
Cause
correctly.
Recommended
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
Action
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
WARNING
FSS-1004
Message
<timestamp>, [FSS-1004], <sequence-number>,, ERROR, <system-name>,
Memory shortage
Probable
Indicates that the system ran out of memory.
Cause
Recommended
Run the memShow command to view memory usage.
Action
Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system.
If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.
Severity
ERROR
FSS-1005
Message
<timestamp>, [FSS-1005], <sequence-number>,, WARNING, <system-
name>, FSS read failure
Probable
Indicates that the read system call to the FSS device failed.
Cause
23-2
Fabric OS Message Reference
Publication Number: 53-1000242-01

Advertisement

Table of Contents
loading

Table of Contents